TCC-100I

Convertidor de RS-232 a RS-422/485

Cantidad

Moxa's serial-to-serial media converters can convert between RS-232, RS-422, and RS-485, which avoids compatibility issues that are often encountered when communicating between different serial interfaces.

Ficha de datos

Isolation
2 kV (I models)
Serial Standards
RS-232, RS-422, RS-485
No. of Ports
2
Baudrate
50 bps to 921.6 kbps (supports non-standard baudrates)
RS-485-2w
Data+, Data-, GND
Power Connector
Terminal block (for DC models)
No. of Power Inputs
1
Input Voltage
12 to 48 VDC
Power Consumption
150 mA @ 12 VDC
Dimensions
67 x 100.4 x 22 mm (2.64 x 3.93 x 0.87 in)
Weight
148 g (0.33 lb)
Installation
DIN-rail mounting (with optional kit), Wall mounting
Housing
Metal
Operating Temperature
-20 to 60°C (-4 to 140°F)
Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
EMC
EN 55032/24
Safety
EN 60950-1, IEC 60950-1
EMI
CISPR 32, FCC Part 15B Class A
EMS
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV IEC 61000-4-5 Surge: Power: 1 kV IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m IEC 61000-4-8 PFMF
Vibration
IEC 60068-2-6
Time
3,017,857 hrs
Standards
Telcordia (Bellcore), GB
Warranty Period
5 years
Connector
Terminal block
Input Current
150 mA @ 12 VDC
Overload Current Protection
Supported
IP Rating
IP30
RS-232
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422
Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w
Tx+, Tx-, Rx+, Rx-, GND
Pull High/Low Resistor for RS-485
1 kilo-ohm, 150 kilo-ohms
RS-485 Data Direction Control
ADDC® (automatic data direction control)
Terminator for RS-485
N/A, 120 ohms, 120 kilo-ohms
Environmental Testing
IEC 60068-2-1 IEC 60068-2-2 IEC 60068-2-3

No hay ninguna opinión por el momento.