MGate MB3170-M-ST-T

Gateway avanzado de Modbus de 1 puerto serie con 1 puerto de fibra 100BaseF(X) multimodo (conector ST), rango de temperatura de -40°C a 75°C

Cantidad

1-port advanced Modbus gateway with 1 100BaseF(X) multi-mode fiber port (ST connectors), -40 to 75°C operating temperature

Ficha de datos

10/100BaseT(X) Ports (RJ45 connector)
2 (1 IP, Ethernet cascade) Auto MDI/MDI-X connection
Magnetic Isolation Protection
1.5 kV (built-in)
Configuration Options
Web Console (HTTP/HTTPS), Device Search Utility (DSU), MGate Manager, Telnet Console
Industrial Protocols
Modbus RTU/ASCII Master, Modbus RTU/ASCII Slave
Modbus TCP Client (Master), Modbus TCP Server (Slave)
Management
ARP, DHCP Client, DNS, HTTP, HTTPS, SMTP, SNMP Trap, SNMPv1/v2c/v3, TCP/IP, Telnet, UDP, NTP Client
MIB
RFC1213, RFC1317
Time Management
NTP Client
Serial Standards
RS-232/422/485 (software selectable)
RS-232/422/485 (software selectable)
No. of Ports
1
1
Baudrate
50 bps to 921.6 kbps
50 bps to 921.6 kbps
Parity
None, Even, Odd, Space, Mark
None, Even, Odd, Space, Mark
Data Bits
7, 8
7, 8
Stop Bits
1, 2
1, 2
Flow Control
DTR/DSR, RTS Toggle (RS-232 only), RTS/CTS
DTR/DSR, RTS Toggle (RS-232 only), RTS/CTS
RS-485-2w
Data+, Data-, GND
Data+, Data-, GND
Power Connector
7-pin terminal block
7-pin terminal block
Input Voltage
12 to 48 VDC
Weight
360 g (0.79 lb)
Housing
Plastic
Operating Temperature
-40 to 75°C (-40 to 167°F)
Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
Freefall
IEC 60068-2-32
EMC
EN 55032/24
Safety
EN 60950-1, UL 508
EMI
CISPR 32, FCC Part 15B Class A
EMS
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 PFMF IEC 61000-4-11 DIPs
Shock
IEC 60068-2-27
Vibration
IEC 60068-2-6, IEC 60068-2-64
Time
1,175,887 hrs
Standards
Telcordia SR332
Warranty Period
5 years
Connector
DB9 male for RS-232
Input Current
510 mA @ 12 VDC
IP Rating
IP30
Hazardous Locations
ATEX, Class I Division 2, IECEx
Maritime
DNV-GL
Max. No. of Client Connections
32
Contact Current Rating
Resistive load: 1 A @ 30 VDC
Resistive load: 1 A @ 30 VDC
RS-232
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422
Tx+, Tx-, Rx+, Rx-, GND
Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w
Tx+, Tx-, Rx+, Rx-, GNDc
Tx+, Tx-, Rx+, Rx-, GNDc
Dimensions (with ears)
29 x 89.2 x 124.5 mm (1.14 x 3.51 x 4.90 in)
29 x 89.2 x 124.5 mm (1.14 x 3.51 x 4.90 in)
Dimensions (without ears)
29 x 89.2 x 118.5 mm (1.14 x 3.51 x 4.67 in)
29 x 89.2 x 118.5 mm (1.14 x 3.51 x 4.67 in)
Pull High/Low Resistor for RS-485
1 kilo-ohm, 150 kilo-ohms
1 kilo-ohm, 150 kilo-ohms
RS-485 Data Direction Control
ADDC® (automatic data direction control)
ADDC® (automatic data direction control)
Terminator for RS-485
120 ohms
120 ohms
Max. No. of Server Connections
32
32